How to plan the decoration socket
With the development of science and technology, people’s lifestyles are constantly changing. The ancients made sunrises and sunsets, and today’s people’s nightlife is getting richer and richer. During the renovation, the number and layout of the outlets show the changes in people's lives from the side. More and more appliances at home require more outlets to meet demand. Many homeowners have inconvenienced their lives because of the unreasonable planning of outlets. Come and talk to everyone today about how to plan the renovation socket to avoid regret.
Part1: Activity Space Qiao Decoration Living Room Bedroom Outlet Planning
The living room and bedroom are the main activity places where people are concentrated, and there are many household appliances. The design should be based on the layout of the layout of the decoration of the building, and should ensure that each major wall has a power outlet.
1, socket number forecast
When considering sockets in the living room and bedroom, etc., ensure that each main wall has a 5-hole socket to meet daily needs. The location of the outlet should be determined according to the design of the house. For example, the outlet for the location of the TV background wall may be more appropriate, and other locations may be determined as required.
2, socket spacing arrangement
If the wall length exceeds 3.6m, the number of sockets should be increased appropriately. The length of the wall is less than 3.6m, and the socket can be placed in the middle of the wall. Set the wall of the TV outlet outlet (this wall is the place where the electrical appliances are placed). At least two 5-hole outlets should be provided. One outlet should be close to the TV outlet outlet and keep a distance of 0.5m or more.
3, socket installation specifications
Because the air conditioner consumes more power, if it is used with a uniform outlet with other electrical appliances, the body of the body is more dangerous. Therefore, a socket must be used alone, and the outlet of the air conditioner outlet must be used with a switch to ensure safety.
4, the installation position of the socket
In the case of known air conditioners, air conditioning outlets are laid out according to the following requirements: No special outlets are required, generally 0.3m above the ground. The split air conditioning outlet should be located 1.8m away from the ground in accordance with the outlet hole of the outlet pipe. If it is a window air conditioner Should be set at the window 1.4m away from the ground, if the cabinet air conditioning should be set at a distance of 0.3m from the appropriate location, otherwise consider split air conditioning air conditioning socket.
Part2: Cooking Environment Safe Kitchen Space Outlet Planning
The kitchen shall be equipped with multiple power outlets at different locations and heights to meet the needs of various electric cookers such as range hoods, sterilizers, microwave ovens, rice cookers, electric water heaters, and refrigerators, according to the layout of the building decoration.
1, socket installation points
The socket in the kitchen should be a splash-proof socket, plus more appliances used in the kitchen, microwave ovens, refrigerators, range hoods, etc. Therefore, the kitchen outlets should constitute a separate circuit and cannot be mixed with other outlets.
2, the installation height of the socket
Refer to the kitchen console, cooktop, shelves, and vegetable tray layout to select the best position for the range hood socket and electric socket. The hood of the range hood is set at 2.0m from the ground, and the electric socket is at a distance of 1.4m or according to the specific positions of the operating platform and the hanging cabinet. The height of the refrigerator socket is generally set to 0.3m from the ground.
3, socket installation precautions
Electric socket should be selected with switch 16A single-phase three-wire socket, such as electric heater has a fixed position should be set not to be placed directly above the electric heating appliance, in order to avoid the personnel arm over the electric heating appliance operation switch. If the rated current of a certain electric appliance exceeds 15A, its corresponding electric outlet shall be provided with a radial power supply directly from the household distribution box to an independent power supply.
Part3: Waterproof and moisture-proof bathroom socket planning
The bathroom is a place where there is a lot of moisture. Therefore, it is forbidden to install a power outlet near the wet place in the toilet, such as a shower area or a bathtub. The power sockets installed in other areas should be splash-proof.
1, the installation position of the socket
When there is an outside window, an exhaust fan junction box or socket should be reserved near the outside window. Since the exhaust air duct is generally near the shower area or bath, the junction box or socket should be installed more than 2.25 m above the ground. 0.6m away from the outside of the shower or bath outside reserved electric water heater outlet and body cleaner power outlet. A beauty and shaving power outlet is installed next to the mirror of the washstand and installed 1.5m to 1.6m above the floor.
2, socket installation precautions
The sockets installed in the bathroom shall have switches and indicator lights. If the sockets are installed in wet locations, it is best to install a waterproof cover on the surface of the socket to prevent water vapor from entering the socket and causing a short circuit.
3, additional socket
Depending on the grade of the residence or at the request of the owner, beard cutter sockets and electric toothbrushes or sockets with isolation transformers can also be provided near the wash basin.
Switch socket
Atomized glass adopts the principle of full patent technology, attaches new liquid crystal material to basic materials such as glass and film, and uses circuit and control technology to make dimming glass products. Atomized glass can be applied in a variety of themed locations. Atomized glass is also called electronically controlled atomized glass, which uses electricity to adjust the transparency and degree of atomization of the atomized glass. The use of intelligent atomized glass on the showcase: with bullet-proof glass, the electricity is transparent when the display is used. In the case of robbery threat, it can be directly controlled by remote control and atomized instantly, so that criminals lose the target of coercion and protect the life and property safety of personnel to the greatest extent. Intelligent atomized glass in the bathroom, toilet use: according to user needs, change the transparency, protect the privacy, but also make the space better visual impact. Intelligent atomized glass is used in office partition: it can achieve the secret function of meeting instantly and improve the overall image of the company.
Window Tint Smart Glass,Window Advertising Glass,Showroom Door Glass,Brand Store Door Glass,Smart Window Film Privacy Electric,Switch Glass Film
Tianqixun Technology , https://www.tqxdisplay.com