Heating Diverter Principles Heating Diverter Tips

Heating in the floor heating is believed to be known by most people, but there are few people who know that the floor heating traps are known. What is a floor heating manifold? For example, warmth is like the body's blood circulation system. A good blood circulation system needs a healthy heart. The warm water manifold is the heart. It evenly distributes boiler water to each branch, and then Then collect the backwater of each way to the boiler for heating and then redistribute it. Next Xiao Bian gave you analyze how the principle of heating water trap and heating water separator to use it.

[heater water separator working principle]

The floor-heating water separator is the control center of the entire indoor geothermal heating. It has the function of dividing and dividing the pressure. When the heat medium flows into the room, it enters the main bar of the water separator after the multifunctional filter. In this step, the filter filters heat. Impurities in the media prevent impurities from entering the underground pipe network and blocking the pipe. The main bar is installed horizontally, so that the same height and pressure equal principle are used to distribute the heat medium evenly to the branch pipes. After the heat exchange system, each branch pipe flows back to the main water column and then flows back into the water inlet. Heating system. In addition, a water mixing device is added to the heating system, that is, after the heat exchange, the temperature of the heat medium (water) is still high. After the water mixing system, the main bar of the water separator flows into the water circulation system again, so that the water is heated. It also saves energy.

[How to use the heating water separator]

How to use warm water separator - first run hot water

The first operation should be gradually injected hot water for the first time to start the geothermal heat, in the hot water, first open the water separator water supply total loop valve, gradually increase the hot water temperature into the pipeline to circulate. Check the water separator interface is not the same, and gradually open the water separator valve. If the water separator and pipe leakage phenomenon should be promptly closed water supply valve and timely contact with the developer or geothermal company.
How to use the floor warmer - The first time to run the exhaust method

In the first operation of the geothermal system, the gas plugs are easily generated due to pressure and water resistance in the pipelines, resulting in non-circulation of the supply and return water and unequal temperatures. As shown in the following figure, the method is: close the heating of the total return valve and the loop adjustment, first open a regulating valve on the water separator, and then open the exhaust valve on the water return bar to discharge the water exhaust, row After the net air is closed, close the valve and open the next valve. And so on, after each row of air is drained and the valve is opened, the system is officially running.

How to use warm water separator - No hot water outlet pipe should be cleaned

Each filter is equipped with a filter in front of it. When there are too many water magazines, the filter should be cleaned in time. If there are too many magazines in the filter, there will be no hot water pipes, no hot geothermal heat, etc. Usually, the filter should be cleaned once a year. The method is: close all the valves on the water separator, open the filter end cover counterclockwise with a live spanner, remove the filter for cleaning, and put it back on the original after cleaning. Open the valve and the geothermal system will work. If the indoor temperature is not lower than 1°C in winter, users are advised to drain the water from the geothermal coil to prevent freezing.

How to use the floor water separator - After the heating is completed, all the water will be discharged

After the heating period is over, the geothermal heat should discharge all the filtering water in the geothermal network. Because the boiler pipeline water contains many tiny particles such as slime, magazines, and rust slag, the water quality is turbid, and the internal diameter of the geothermal pipe network is very fine. The calcium, magnesium, and salt contained in the water will precipitate and hard scales will be formed on the ground. On the inner wall of the pipe network, the bend is even more serious, and even if it is flushed by the pressurized water flow, it is also the reason that the floor heating should be cleaned.

Summary: We have introduced the working principle of the heating water separator and how to use it. We hope to help everyone's life.

Warm water separator, heating and cooling principle, siphon principle, color matching skills

Exposed Shower Sets